Outpatient Surgery Magazine

Are You Ready for Ebola? - November 2014 - Subscribe to Outpatient Surgery Magazine

Outpatient Surgery Magazine, providing current information on Surgical Services, Surgical Facility Administration, Outpatient Surgery News and Trends, OR Excellence and more.

Issue link: http://outpatientsurgery.uberflip.com/i/416112

Contents of this Issue

Navigation

Page 102 of 114

1 0 3 N O V E M B E R 2 0 1 4 | O U T P AT I E N T S U R G E R Y M A G A Z I N E O N L I N E THINKING OF BUYING ... probes, for instance, a wrapped tray of implant plates and screws for the podiatry procedures you're going to host may not be allowable according to their manufacturer's cycle requirements. In that case, you can either invest in a cycle that provides the necessary cycles, or outsource the reprocessing of some of your instruments. How are we using the sterilizer? There are lim- its on what you can reprocess in a tabletop sterilizer. These units are validated for specif- ic load sizes, weights and densities, and circumventing these limits, such as by attempting to reprocess an oversized package or by stacking trays, can adversely impact the units' sterilization and drying functions. Be sure to train your staff on their proper use, testing and main- tenance in order to comply with best practices. OSM Ms. Chobin ( nancy.chob in@att.net ) is the assistant vice president of sterile processing services for Barnabas Health in West Orange, N.J., and the former executive director of the Certification Board for Sterile Processing and Distribution. 3 With the emergence of many aggressive, infectious organisms, there is an ever-increasing need for efficient, effective instrument processing in your practice. The M11 is the largest member of the Ritter family of autoclaves. Its unique 11" x 18" chamber gives it the distinction of having the largest sterilizing capacity of any standard countertop sterilizer on the market, making it perfect for larger packs and instruments. OTHER FEATURES INCLUDE: • Exclusive automatic-opening door design allows for ease of use and a quick drying time • Steam-Flush Pressure Pulse Air Removal System designed to ensure proper steam penetration • Front fill and drain make filling and cleaning fast and easy • The M11's four preprogrammed cycles are designed to save on labor and provide extra confidence in sterilization For more information, call 1-800-MIDMARK or visit midmark.com/outpatient. Midmark Corporation, Versailles, OH 45380 Ritter M11 UltraClave ® Automatic Sterilizer

Articles in this issue

Links on this page

Archives of this issue

view archives of Outpatient Surgery Magazine - Are You Ready for Ebola? - November 2014 - Subscribe to Outpatient Surgery Magazine