Outpatient Surgery Magazine - Subscribers

What Will the OR of the Future Look Like? - July 2014 - Outpatient Surgery Magazine

Outpatient Surgery Magazine, providing current information on Surgical Services, Surgical Facility Administration, Outpatient Surgery News and Trends, OR Excellence and more.

Issue link: http://outpatientsurgery.uberflip.com/i/341153

Contents of this Issue

Navigation

Page 53 of 114

5 4 O U T P AT I E N T S U R G E R Y M A G A Z I N E O N L I N E | J U LY 2 0 1 4 use, not even for the next procedure. 1 3. Where can I find the time and temperature settings for IUSS? You'll find the time and temperature settings for each item to be steril- ized using IUSS in the manufacturer's written instructions for use. The instructions for use may or may not require a dry time and may require a cycle length or temperature different than the traditional times. Because of the variations, follow the manufacturers' written instructions for use and adjust the sterilizer settings for each item or group of items having identical requirements. 1 4. The OR sterilizer is broken and I need to process an instrument by IUSS. Could I perform IUSS in an autoclave in the sterile processing area? Yes, but only if the sterilizer is capable of achieving the required set- tings. The instruments should also be processed in a rigid container, intended for IUSS, which facilitates the safe transportation to the ster- ile field. The location for sterilization does not depend on the type of sterilization — IUSS vs. terminal. Rather, it depends on the sterilizer being able to meet the requirements for sterilization. 1,2 5. May I use IUSS for implants? No. Immediate-use steam sterilization should not be used for implants, except in emergency situations when no other option is available. Follow the manufacturer's written instructions for use when determin- ing which cycle to use. Place a biological indicator and a class 5 chemi- cal integrating indicator in each load. Don't use the implant until the results of the biological indicator is known. If you happen to use an implant before the biological indicator results are known and the bio- logical indicator is found to be positive, notify the surgeon and infec- S T E R I L I Z A T I O N Symmetry Surgical's broad portfolio brings together more than 300 years of experience with quality product lines that clinicians trust to deliver best-in-class patient care. symmetrysurgical.com Instruments | Sterilization Solutions | Retractors | Energy Contact your sales representative at 800.251.3000 or learn more at FlashPak.com Our FlashPak ® immediate-use steam sterilization system has met all clinical standards for 25 years — and counting. 6]a^WbOZ^`]dS\[]PWZSÆSZR • Closed system • Fully automatic operation Symmetry Surgical's FlashPak ® is the First Name in Immediate-use Steam Sterilization OSE_1407_part2_Layout 1 7/3/14 8:49 AM Page 54

Articles in this issue

Links on this page

Archives of this issue

view archives of Outpatient Surgery Magazine - Subscribers - What Will the OR of the Future Look Like? - July 2014 - Outpatient Surgery Magazine